Sign In | Join Free | My chinaqualitycrafts.com
China FLY AUTOMATION logo
FLY AUTOMATION
Automation Industry Expert . Focused on Pneumatic Components 15 years!
Verified Supplier

17 Years

Home > Pulse Jet Valves >

CA35T G1 1/2" 860KPA Air Pulse Valve

FLY AUTOMATION
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

CA35T G1 1/2" 860KPA Air Pulse Valve

Brand Name : FLY, AIRWLOF or OEM

Model Number : CA35T

Certification : ISO 9001,CE

Place of Origin : China

MOQ : 1 piece

Price : price negotiable

Payment Terms : T/T in advance,Western Union,Paypal,Credit card

Supply Ability : 2000 pcs/month

Delivery Time : 5 working days

Packaging Details : carton

Power : Pneumatic

Valve body material : Aluminium (diecast)

Pressure : 30-860KPA

Temperature : Normal Temperature

Voltage : AC220V AC110V DC12V DC24V

Contact Now

CA35T air pulse valve G1 1/2" Electronic control THREADED dust collector

Description

High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Construction
Body: Aluminium (diecast)
Ferrule: 304 SS
Armature: 430FR SS
Seals: Nitrile or fluororubber (reinforced)
Spring: 304 SS
Screws: 302 SS
Diaphragm Seat: PA-6 (standard), fluororubber coated mild steel or High Density PE Refer to Q Series Solenoid product data sheet for solenoid construction details.
Maintenance
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.
Approvals
Integrally piloted valves meet the requirements of:
. Atex II 2D Mechanical
. CSA (C&US)
C22.2 No. 139-1982 UL Std No. 429
. C-Tick - integral pilots
. EMC (89/336/CE) - integral pilots
Installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.

Pressure Range: 30(5)-860(125) kPA(Psi)
Temperature Range: Nitrite Seals: -40°C (-40°F) to 82°C(179.6°F) fluororubber Seals: -29°C (-20.2°F) to 232°C (449.6°F)

Weights:
Size Integral Pilot (CA) Kg (lbs) Remote Pilot (RCA) Kg (lbs)
35 1.04(2.28) 0.83(1.83)

Maintenance Kits

Model Nitrile fluororubber Low Temperature -60°C (-76°F) Min. Includes
CA/RCA35T K3500 K3501 K3502 Diaphragm kits include main and secondary diaphragms (where required) and all springs.These kits are for discontinued valves. o-ring, armature assembly, armature spring, ferrule

4.Product Characteristics and Performance:

Item Code Nom. Size mm Port Size inch Number of diaphragms Kv Flow Cv
CA/RCA-10T 10 10 3/8 1 2.5 2.9
CA/RCA-20T 20 20 3/4 1 12 14
CA/RCA-25T 25 25 1 1 20 23
CA/RCA-35T 35 40 1.5 1 36 42
CA/RCA-45T 45 40 1.5 2 44 51
CA/RCA-50T 50 50 2 2 76 88
CA/RCA-62T 62 62 2.5 2 91 106
CA/RCA-76T 76 76 3 2 144 167


5.Dimension(mm and inch):

CA35T G1 1/2" 860KPA Air Pulse Valve

Working principle
Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.
The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.
The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning.

After-sale Service
We can provide a series of after-sale service, such as product introduction, mounting, debugging, technical support and so on.

CA35T G1 1/2" 860KPA Air Pulse ValveCA35T G1 1/2" 860KPA Air Pulse Valve


Product Tags:

G1 air pulse valve

      

FLY/AIRWOLF CA35T air pulse valve

      

860KPA air pulse valve

      
Quality CA35T G1 1/2" 860KPA Air Pulse Valve for sale

CA35T G1 1/2" 860KPA Air Pulse Valve Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: FLY AUTOMATION
*Subject:
*Message: